Can a shower and toilet share a vent?

So yes the shower can also be vented by the wet vent along with the toilet. There is one major stipulation when wet venting multiple fixtures when a toilet is one of them: the toilet must be the last fixture connected to the wet vent.

Can a shower and toilet share a drain?

In short, it is possible to connect the toilet drainage line and the shower drainage line, as long as they both have separate waste trap arms. However, do note that combining them may also lead to blockages, which can cause smells to come from certain drains.

Can tub and toilet Share vent?

1.5″ pipe can not serve as wet vent on a toilet and max 2 fixture units. A 2″ pipe can serve a toilet and a maximum 4 fixture units draining into it. (Sinks, tubs, showers all have 1.5 fixtures units each). As a general rule, you will just be able to vent 2 fixtures on a toilet wet vent.


Can two plumbing fixtures share a vent?

Yes they both can share a vent.

How close does a vent need to be to a toilet?

According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.


How to identify and correct a venting problem with a shower drain.



How far can a vent be from a shower?

The connection between the fixture drain and the horizontal drain and vent pipe is the only vertical pipe of a combination drain and vent system. 8 feet is the maximum vertical distance.

Does each toilet need its own vent?

“Does a toilet need a vent?” And the answer is yes, your toilet has to have a vent. For more information on the great importance of plumbing vents, read our plumbing vent article here. And the size of this vent pipe depends on your local plumbing code.

How many plumbing fixtures can share vents?

A horizontal wet vent could have as few as two fixtures or as many as ten fixtures but not more than two fixtures of any type can be connected to the system. Each wet vented fixture drain shall connect independently to the horizontal wet vent.

Can 2 toilets share a vent?

The waste lines can usually be tied into the same stack if the house has more than one toilet. They may need their own stack if they are on opposite sides. Two vent openings on the roof are needed since the stacks must be vented.


How many fixtures can you put on a 2 vent?

The Plumbing Code states that a vent can handle 24 fixture units. A bathroom sink of 1.0 F.U., a bathtub of 2.0 F.U., and a shower of 2.0 F.U.

How do you vent a toilet and shower?

The most common configuration is to feed 2" PVC down from the ceiling within the wall behind the toilet. The vent pipe connects into the toilet drain pipe. The sink drain pipe and the tub/shower drain pipe are vented with 1.5" pipe that branches off from the 2" PVC mainline.

Can you use one vent for the whole bathroom?

In new construction, the simplest way to vent a bathroom group is usually to install a single vertical vent pipe behind the bathroom sink. This works as long as all the plumbing fixtures connect to the main drain line in the floor within 6 to 10 lineal feet of the sink drain.

Do plumbing vents have to go through the roof?

It does not have to go through the roof. From the plumbing code (I have the 2003 edition), P3103: It must not be less than 4 feet directly beneath a door, openable window or other air intake of the building or adjacent building.


Can you switch toilet and shower?

Showers and toilets have one thing in common: plumbing. And while you can't always interchange things in a home when working on a remodel project, you can convert your shower into an area for a toilet simply by doing some demolition and remodel work, along with replacing the plumbing.

Why does my toilet back up into the shower?

If you see used water from the toilet backing up into shower or tub drains though, that's a sign of a clogged sewer main. Since something is blocking the wastewater, it has no other choice but to back up. Since your toilet is set higher, the water is more likely to rise out of the lower tub or shower drain.

Can you vent two bathrooms together?

Well, you can't! You'd often blow air from one bathroom into the other, and local building inspectors wouldn't approve it. But while you can't have two fans with one vent, you can make one fan and one vent serve two bathrooms.

Can sink and toilet shared vent?

A general rule is that you can only vent 2 fixtures on a toilet wet vent. The sink drain has a toilet vent through it. The toilet drain should be 3′′, the sink drain is 1.5′′, the shared sink drain/toilet vent area should be 2′′, and the vent going up should be 1.5′′.


How many fixtures can be on a 3 vent?

A 3-inch (76 mm) soil stack with a stack vent serving as the required vent extension to the outdoors, connecting to a 3-inch (76 mm) building drain, must have at least a 1½-inch (38 mm) stack vent [maximum of 102 fixture units served and a maximum 25-foot (7620 mm) developed length] in accordance with Section 906.1 and ...

How many plumbing vents should a house have?

At least one main vent stack is required for every building that has plumbing when connecting separately to the sewer for the building or its septic tank. The stack has to run the most direct route through open air or be ventilated to extend to open air.

How does a cheater vent work?

A cheater vent (or air admittance valve) is a vent that comes off the fixture -- for example, a sink in a new powder room -- and is buried in the wall. (You can usually hear them sucking in air and gurgling behind the wall when the fixture drains.)

What happens if a toilet is not vented?

Poorly-vented drain lines will not be able to effectively move wastewater and solid waste out of your building. This could lead to problems such as overflowing drains, backed-up toilets, and similar plumbing issues.


Can you use a cheater vent for a toilet?

Don't worry if you do not have a vent pipe in your house, or if it is blocked and you can't fix it. Instead of thinking about massive construction projects, you can use an Air Admittance Valve, well-known as a cheater vent.

Can toilet vent be upstream?

A toilet vent can be upstream. The purpose of the vent pipe is to allow the sewer's gases to escape from the house's roof rather than inside the house. A vent also allows oxygen to enter into the sewer pipes, which allows the waste to break down and prevents clogging.

Does a shower drain need a vent pipe?

A plumbing vent helps the shower drain function properly. Your house's drainpipes may have sewer gases in them at any given time. These gases may seep into the pipes from the sewer drainpipe connection, making their way up the drainpipes in the house.